Alle angegebene Preise in € !
Operating Parameters:
Maximum temperature for Cemented Needle
is 50° C
and all others 115° C.
Maximum test pressure is 6 bar.
|
|
For use with gas and
liquids. |
Ordering Information
| Volume | 1 ml | 1,25 ml | 2,5 ml | 5 ml | 10 ml | 25 ml | 50 ml | 100 ml | |
| Model | 1001 | 1001.25 | 1002 | 1005 | 1010 | 10251) | 10501) | 11001) | |
| Gauge** | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | |
|
LTN (Cemented Needle) point style 2 |
|
81317/ 55,70/Stck. | 82017/ 95,90/Stck. | 81417/ 49,90/Stck. | 81517/ 69,30/Stck. | 81617/ 82,50/Stck. | |||
|
LTN (Cemented Needle) point style 3 |
81316/ 57,40/Stck. | 81416/ 58,50/Stck. | 81516 / 70,60/Stck. | 81616/ 84,10/Stck. | |||||
|
LTN (Cemented Needle) point style 5 |
81343/ 62,90/Stck. | 81443 / 64,90/Stck. | 81543 / 81,70/Stck. | 81643/ 88,80/Stck. | |||||
| LTSN (Cemented
Needle) Specify needle gauge, length, point style, and whether electro-tapered |
81314/ 108,40/Stck. | 81414 / 113,10/Stck. | 81514 / 126,50/Stck. | 81614/ 139,10/Stck. | |||||
| RN (Removable
Needle) point style 2 |
81330/ 86,40/Stck. | 81430 / 91,90/Stck. | 81530 / 88,80/Stck. | 81630/ 108,40/Stck. | |||||
| RN (Removable
Needle) point style 3 |
81365/ 80,90/Stck. | ||||||||
| RN (Removable
Needle) Syringe Needle not included |
7649-01/ 78,30/Stck. | 7650-01/ 81,70/Stck. | 7651-01/ 89,60/Stck. | 7652-01/ 106,10/Stck. | |||||
| LT (Luer Tip) Needle not included |
81301/ 51,80/Stck. | 82001/ 95,90/Stck. | 81401 / 53,40/Stck. | 81501 / 58,00/Stck. | 81601/ 68,90/Stck. | ||||
| SampleLock
Syringe point style 2 |
81356/ 192,50/Stck. | 81456/ 206,60/Stck. | 81556/ 246,70/Stck. | 81656/ 246,70/Stck. | 86326/ 380,30/Stck. | 86336/ 528,00/Stck. | 86346/ 618,40/Stck. | ||
| TLL (TEFLON®
Luer Lock) w/o slots Needle not included |
81320/ 55,70/Stck. | 81420 / 55,70/Stck. | 81520 / 65,10/Stck. | 81620/ 71,80/Stck. | 82520/ 203,50/Stck. | 85020/ 269,50/Stck. | 86020/ 346,50/Stck. | ||
| TLL with
slots Needle not included |
81327/ 80,10/Stck. | 81427 / 70,50/Stck. | 81527 / 85,60/Stck. | 81627/ 94,30/Stck. | 82527/ 190,90/Stck. | 85027/ 237,30/Stck. | |||
| TLL wlo
flange, w/o slots Needle not included |
82521/ 182,30/Stck. | 85021/ 256,10/Stck. | |||||||
| TLL
wlo flange, with slots Needle not included |
|
82525/ 189,40/Stck. | 85025/ 237,30/Stck. | ||||||
| TLL-XL
Needle not included |
201812/ 68,40/Stck. | 201817/ 68,80/Stck. | 201822/ 67,60/Stck. | 201827/ 82,50/Stck. | |||||
| DX,
Diluter with stop Needle not included |
81326/ 150,90/Stck. | ||||||||
| AD,
AccuDil® with stop Needle not included |
201200/ 78,50/Stck. |
|
201250/ 78,50/Stck. | 201300/ 108,40/Stck. | 201350/ 154,80/Stck. | 201400/ 199,60/Stck. | |||
| DAD, Diluter AccuDil® with stop Needle not included | 201700/ 143,80/Stck. |
|
|||||||
| C, CHEM Needle not included | 81360/ 95,90/Stck. | 81460 / 95,90/Stck. | 81560 / 110,80/Stck. | 81660/ 110,80/Stck. | |||||
| C-XP Needle not included | 201760/ 52,60/Stck. | 201770/ 54,10/Stck. | 201780/ 55,20/Stck. | ||||||
| W Needle not included | 81610/ 141,20/Stck. | ||||||||
| PB600 Repeating Dispenser Syringe not included |
|
83700/ 121,00/Stck. | 83700/ 121,00/Stck. | 83700 / 121,00/Stck. |
|
1) TLL male luer fitting is made of Kel-F® (CTFE) material instead of TEFLON® PTFE
Replacement Parts

| Volume | 1 ml | 2,5 ml | 5 ml | 10 ml | 25 ml | 50 ml | 100 ml | |
| Description | Model | 1001 | 1002 | 1005 | 1010 | 1025 | 1050 | 1100 |
| 1. Plunger
Assembly LT/LTN/TLL w/ & w/o Slots |
1359-01/ 23,50/Stck. | 1360-01/ 23,50/Stck. | 13230/ 26,50/Stck. | 13231/ 26,50/Stck. | 132711)/ 69,10/Stck. | 13272/ 82,50/Stck. | 13240/ 79,50/Stck. | |
| Plunger Assembly RN | 1359-01/ 23,50/Stck. | 1360-01/ 23,50/Stck. | 13230/ 26,50/Stck. | 13231/ 26,50/Stck. | ||||
| Plunger Assembly Samplelock | 1343-01/ 93,50/Stck. | 1615-02/ 286,90/Stck. | 1615-03/ 312,70/Stck. | |||||
| Plunger Assembly TLLX | 200920/ 41,00/Stck. | |||||||
| Plunger Assembly TLL-XL | 201815/ 25,50/Stck. | 201820/ 24,50/Stck. | 201825/ 26,60/Stck. | 201829/ 30,60/Stck. | ||||
| Plunger Assembly DX | 1578-01/ 37,30/Stck. | |||||||
| Plunger Assembly AD/DAD | 201220/ 34,70/Stck. | 201270/ 35,30/Stck. | 201301/ 26,50/Stck. | 201370/ 75,30/Stck. | 13271/ 69,10/Stck. | |||
| Plunger Assembly C | 1359-01/ 23,50/Stck. | 1360-01/ 23,50/Stck. | 13291/ 23,90/Stck. | 13292/ 27,00/Stck. | ||||
| Plunger Assembly C-XP | 201765/ 23,50/Stck. | 201775/ 23,50/Stck. | 201785/ 23,50/Stck. | |||||
| 2. RN Nut | 30902/ 5,00/Stck. | 30902/ 5,00/Stck. | 30902/ 5,00/Stck. | 30902/ 5,00/Stck. | 30902/ 5,00/Stck. | 30902/ 5,00/Stck. | 30902/ 5,00/Stck. | |
| Needles | siehe Nadelseite | |||||||
1) TLL male luer fitting is made of Kel-F® (CTFE) material instead of TEFLON® PTFE